PLoS One ; 17(10): e0273402, 2022.
Article in English | MEDLINE | ID: covidwho-2079731

ABSTRACT

BACKGROUND: The pathophysiology of COVID-19 remains poorly understood. We aimed to estimate the contribution of intrapulmonary shunting and ventilation-to-perfusion (VA/Q) mismatch using a mathematical model to construct oxygen-haemoglobin dissociation curves (ODCs). METHODS: ODCs were constructed using transcutaneous pulse oximetry at two different fractions of inspired oxygen (FiO2). 199 patients were included from two large district general hospitals in the South East of England from 1st to 14th January 2021. The study was supported by the National Institute of Health Research (NIHR) Clinical Research Network. RESULTS: Overall mortality was 29%. Mean age was 68.2 years (SEM 1·2) with 46% female. Median shunt on admission was 17% (IQR 8-24.5); VA/Q was 0.61 (IQR 0.52-0.73). Shunt was 37.5% higher in deaths (median 22%, IQR 9-29) compared to survivors (16%, 8-21; p = 0.0088) and was a predictor of mortality (OR 1.04; 95% CI 1.01-1.07). Admission oxygen saturations were more strongly predictive of mortality (OR 0.91, 95% CI 0.87-0.96). There was no difference in VA/Q mismatch between deaths (0.60; IQR 0.50-0.73) and survivors (0.61; IQR 0.52-0.73; p = 0.63) and it was not predictive of mortality (OR 0.68; 95% CI 0.18-2.52; p = 0.55). Shunt negatively correlated with admission oxygen saturation (R -0.533; p<0.0001) whereas VA/Q was not (R 0.1137; p = 0.12). INTERPRETATION: Shunt, not VA/Q mismatch, was associated with worsening hypoxia, though calculating shunt was not of prognostic value. This study adds to our understanding of the pathophysiology of hypoxaemia in COVID-19. Our inexpensive and reliable technique may provide further insights into the pathophysiology of hypoxia in other respiratory diseases.


Subject(s)
COVID-19 , Lung Diseases , Humans , Female , Aged , Male , Ventilation-Perfusion Ratio/physiology , Hypoxia , Oximetry/methods , Oxygen/physiology
2.
PLoS One ; 17(8): e0273214, 2022.
Article in English | MEDLINE | ID: covidwho-2021908

ABSTRACT

Busana et al. (doi.org/10.1152/japplphysiol.00871.2020) published 5 patients with COVID-19 in whom the fraction of non-aerated lung tissue had been quantified by computed tomography. They assumed that shunt flow fraction was proportional to the non-aerated lung fraction, and, by randomly generating 106 different bimodal distributions for the ventilation-perfusion ([Formula: see text]) ratios in the lung, specified as sets of paired values {[Formula: see text]}, sought to identify as solutions those that generated the observed arterial partial pressures of CO2 and O2 (PaCO2 and PaO2). Our study sought to develop a direct method of calculation to replace the approach of randomly generating different distributions, and so provide more accurate solutions that were within the measurement error of the blood-gas data. For the one patient in whom Busana et al. did not find solutions, we demonstrated that the assumed shunt flow fraction led to a non-shunt blood flow that was too low to support the required gas exchange. For the other four patients, we found precise solutions (prediction error < 1x10-3 mmHg for both PaCO2 and PaO2), with distributions qualitatively similar to those of Busana et al. These distributions were extremely wide and unlikely to be physically realisable, because they predict the maintenance of very large concentration gradients in regions of the lung where convection is slow. We consider that these wide distributions arise because the assumed value for shunt flow is too low in these patients, and we discuss possible reasons why the assumption relating to shunt flow fraction may break down in COVID-19 pneumonia.


Subject(s)
COVID-19 , Humans , Lung , Oxygen , Perfusion , Pulmonary Gas Exchange/physiology , Ventilation-Perfusion Ratio/physiology
3.
Crit Care ; 25(1): 331, 2021 09 13.
Article in English | MEDLINE | ID: covidwho-1413915

ABSTRACT

BACKGROUND: Mortality due to COVID-19 is high, especially in patients requiring mechanical ventilation. The purpose of the study is to investigate associations between mortality and variables measured during the first three days of mechanical ventilation in patients with COVID-19 intubated at ICU admission. METHODS: Multicenter, observational, cohort study includes consecutive patients with COVID-19 admitted to 44 Spanish ICUs between February 25 and July 31, 2020, who required intubation at ICU admission and mechanical ventilation for more than three days. We collected demographic and clinical data prior to admission; information about clinical evolution at days 1 and 3 of mechanical ventilation; and outcomes. RESULTS: Of the 2,095 patients with COVID-19 admitted to the ICU, 1,118 (53.3%) were intubated at day 1 and remained under mechanical ventilation at day three. From days 1 to 3, PaO2/FiO2 increased from 115.6 [80.0-171.2] to 180.0 [135.4-227.9] mmHg and the ventilatory ratio from 1.73 [1.33-2.25] to 1.96 [1.61-2.40]. In-hospital mortality was 38.7%. A higher increase between ICU admission and day 3 in the ventilatory ratio (OR 1.04 [CI 1.01-1.07], p = 0.030) and creatinine levels (OR 1.05 [CI 1.01-1.09], p = 0.005) and a lower increase in platelet counts (OR 0.96 [CI 0.93-1.00], p = 0.037) were independently associated with a higher risk of death. No association between mortality and the PaO2/FiO2 variation was observed (OR 0.99 [CI 0.95 to 1.02], p = 0.47). CONCLUSIONS: Higher ventilatory ratio and its increase at day 3 is associated with mortality in patients with COVID-19 receiving mechanical ventilation at ICU admission. No association was found in the PaO2/FiO2 variation.


Subject(s)
COVID-19/therapy , Respiration, Artificial/methods , Respiratory Distress Syndrome/therapy , Ventilation-Perfusion Ratio/physiology , Aged , Aged, 80 and over , COVID-19/epidemiology , COVID-19/physiopathology , Cohort Studies , Critical Care/methods , Critical Care/trends , Female , Hospital Mortality/trends , Humans , Intensive Care Units/trends , Male , Middle Aged , Prognosis , Prospective Studies , Pulmonary Ventilation/physiology , Respiration, Artificial/trends , Respiratory Distress Syndrome/epidemiology , Respiratory Distress Syndrome/physiopathology , Retrospective Studies , Spain/epidemiology
4.
J Appl Physiol (1985) ; 130(3): 865-876, 2021 03 01.
Article in English | MEDLINE | ID: covidwho-1028125

ABSTRACT

COVID-19 infection may lead to acute respiratory distress syndrome (CARDS) where severe gas exchange derangements may be associated, at least in the early stages, only with minor pulmonary infiltrates. This may suggest that the shunt associated to the gasless lung parenchyma is not sufficient to explain CARDS hypoxemia. We designed an algorithm (VentriQlar), based on the same conceptual grounds described by J.B. West in 1969. We set 498 ventilation-perfusion (VA/Q) compartments and, after calculating their blood composition (PO2, PCO2, and pH), we randomly chose 106 combinations of five parameters controlling a bimodal distribution of blood flow. The solutions were accepted if the predicted PaO2 and PaCO2 were within 10% of the patient's values. We assumed that the shunt fraction equaled the fraction of non-aerated lung tissue at the CT quantitative analysis. Five critically-ill patients later deceased were studied. The PaO2/FiO2 was 91.1 ± 18.6 mmHg and PaCO2 69.0 ± 16.1 mmHg. Cardiac output was 9.58 ± 0.99 L/min. The fraction of non-aerated tissue was 0.33 ± 0.06. The model showed that a large fraction of the blood flow was likely distributed in regions with very low VA/Q (Qmean = 0.06 ± 0.02) and a smaller fraction in regions with moderately high VA/Q. Overall LogSD, Q was 1.66 ± 0.14, suggestive of high VA/Q inequality. Our data suggest that shunt alone cannot completely account for the observed hypoxemia and a significant VA/Q inequality must be present in COVID-19. The high cardiac output and the extensive microthrombosis later found in the autopsy further support the hypothesis of a pathological perfusion of non/poorly ventilated lung tissue.NEW & NOTEWORTHY Hypothesizing that the non-aerated lung fraction as evaluated by the quantitative analysis of the lung computed tomography (CT) equals shunt (VA/Q = 0), we used a computational approach to estimate the magnitude of the ventilation-perfusion inequality in severe COVID-19. The results show that a severe hyperperfusion of poorly ventilated lung region is likely the cause of the observed hypoxemia. The extensive microthrombosis or abnormal vasodilation of the pulmonary circulation may represent the pathophysiological mechanism of such VA/Q distribution.


Subject(s)
COVID-19/physiopathology , Ventilation-Perfusion Ratio/physiology , Adult , Aged , COVID-19/metabolism , Cardiac Output/physiology , Female , Hemodynamics/physiology , Humans , Lung/metabolism , Lung/physiopathology , Male , Middle Aged , Oxygen/metabolism , Perfusion/methods , Pulmonary Circulation/physiology , Pulmonary Gas Exchange/physiology , Respiration , Retrospective Studies , SARS-CoV-2/pathogenicity
5.
Nat Commun ; 11(1): 4883, 2020 09 28.
Article in English | MEDLINE | ID: covidwho-801570

ABSTRACT

Early stages of the novel coronavirus disease (COVID-19) are associated with silent hypoxia and poor oxygenation despite relatively minor parenchymal involvement. Although speculated that such paradoxical findings may be explained by impaired hypoxic pulmonary vasoconstriction in infected lung regions, no studies have determined whether such extreme degrees of perfusion redistribution are physiologically plausible, and increasing attention is directed towards thrombotic microembolism as the underlying cause of hypoxemia. Herein, a mathematical model demonstrates that the large amount of pulmonary venous admixture observed in patients with early COVID-19 can be reasonably explained by a combination of pulmonary embolism, ventilation-perfusion mismatching in the noninjured lung, and normal perfusion of the relatively small fraction of injured lung. Although underlying perfusion heterogeneity exacerbates existing shunt and ventilation-perfusion mismatch in the model, the reported hypoxemia severity in early COVID-19 patients is not replicated without either extensive perfusion defects, severe ventilation-perfusion mismatch, or hyperperfusion of nonoxygenated regions.


Subject(s)
Betacoronavirus , Coronavirus Infections/complications , Coronavirus Infections/physiopathology , Hypoxia/etiology , Hypoxia/physiopathology , Lung Diseases/etiology , Lung Diseases/physiopathology , Lung/blood supply , Lung/physiopathology , Models, Biological , Pneumonia, Viral/complications , Pneumonia, Viral/physiopathology , Pulmonary Circulation/physiology , COVID-19 , Computer Simulation , Coronavirus Infections/epidemiology , Humans , Hypoxia/therapy , Lung Diseases/therapy , Mathematical Concepts , Models, Cardiovascular , Oxygen Inhalation Therapy , Pandemics , Pneumonia, Viral/epidemiology , SARS-CoV-2 , Time Factors , Vasoconstriction/physiology , Vasodilation/physiology , Ventilation-Perfusion Ratio/physiology